Part Number Hot Search : 
FAN5632 015C2 21012 78M16 015BDTR 5926B AT24C02 B4406
Product Description
Full Text Search
 

To Download CE-300-1001 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 300 Watts
CE-300 Series
Features
* Universal 85-264 VAC Input * Harmonic Current Per EN 61000-3-2 * Compact 4.9"x 8.5"x 1.95" Size * Internal Fan * One to Five Outputs * Optional Remote On/Off * Remote Sense Outputs 1 & 2 * Class B Emissions Per EN 55022 * EMC Compliant To EN 61000-4-2, 3, 4, 5 * Optional Power Fail Signal * 2 Year Warranty * EN 60950 ITE Certification
All specifications are maximum at 25C unless otherwise stated and are subject to change without notice.
Output Specifications
Total Output Power Output Voltage Centering Source Regulation Load Regulation Cross Regulation Output Voltage Adjust Span Resolution Output Noise Source Freq. Switching Freq. Total (20 MHz) Turn On Overshoot Transient Response Voltage Deviation Recovery Time Load Change Output Overvoltage Protection (Optional) Output Overpower Protection Output Overcurrent Protection Hold Up Time Start Up Time 300W Output 1-5: 0.5% (All outputs at 50% rated load)
Outputs 1-5: 0.5% Outputs 1-5: 1% (10-100%) (Output 1 load Output 2-5: 0.5% varied 50-100%) Outputs 1,2 & 3: 95% To 105% 1% (Output under Outputs 1-5: 0.5% test at 100% Outputs 1-5: 1% rated load) Outputs 1-5: 1% None Outputs 1-5 5% 2mS 50% To 100% Output 1: 120% to 150% shuts down all outputs. Cycle input to restart. 340 Watts Min., outputs cycle on/off, auto recovery 110% Min., Outputs 2,3,4 & 5 20mS Min, 300W Output 120V Input 3 Seconds
Input Specifications Safety Specifications
General Protection Class: Overvoltage Category: Pollution Degree: UL 1950, Third Edition I II 2 Source Voltage Frequency Range Source Current True RMS Peak Inrush Peak Repetitive Harmonic Distortion Efficiency Power Factor 85 - 264 Volts Continuous 47-63 Hz 5.8A At 85V Input 20A 8.2A At 85V Input 0.05 .68-.80 (Varies by model) 0.90 (300 Watts, 230V)
Underwriters Laboratories File E137708 UL Recognition Mark for Canada File E137708 TUV License B 99 12 30824 011
CAN/CSA-C22.2 No. 950-M95
Environmental Specifications
Ambient Operating Temperature Range Ambient Storage Temperature Range Temperature Coefficient Shock Vibration 0 C to +50 C -40 C to +85 C Outputs 1-5: 0.02%/C Transit Drop per MIL-STD-810E Method 516.4 Procedure IV MIL-STD-810E, Method 514.4, Category 1
EN 60950/All:1997 VDE 0805 Low Voltage Directive
Model Listing
MODEL CE-300-5001 CE-300-5002 CE-300-5003 CE-300-5004 CE-300-5005 CE-300-5006 CE-300-4001 CE-300-4002 CE-300-4003 CE-300-4004 CE-300-4005 CE-300-4006 CE-300-4009 CE-300-4011 CE-300-3001 CE-300-3002 CE-300-3003 CE-300-3004 CE-300-3006 CE-300-2001 CE-300-2002 CE-300-2003 CE-300-2004 CE-300-1001 CE-300-1002 CE-300-1003 CE-300-1004 OUTPUT 1 OUTPUT 2 OUTPUT 3 OUTPUT 4 OUTPUT 5 +5V/40A +24V/4A +12V/6A -5V/1A -12V/2A +5V/40A +12V/8A -12V/6A -5V/1A +24V/2A +5V/40A +12V/8A +24V/3A -15V/1A +15V/2A +5V/40A +24V/4A 24V/3A -12V/1A +12V/2A +24V/8A +12V/8A +5V/6A -15V/1A +15V/2A +24V/8A 24V/4A +5V/6A -15V/1A +15V/2A +5V/40A +12V/8A -5V/5A -12V/2A +5V/40A +24V/4A +12V/6A -12V/2A +5V/40A +24V/4A +15V/4A -15V/2A +24V/8A +12V/8A +5V/6A -12V/2A +5V/40A -5.2V/12A +12V/6A -12V/2A +24V/8A +12V/8A -12V/1.5A 5V/2A +24V/8A +12V/8A +5V/10A -12V/2A +5V/40A +3.3V/12A +12V/2A -12V/2A +5V/40A +12V/8A -12V/6A +5V/40A +12V/8A +24V/3A +5V/40A +15V/6A -15V/4A +12V/16A -12V/8A +5V/6A +5V/40A +3.3V/12A +12V/2A +5V/40A +24V/4A +12V/16A -12V/8A +15V/13A -15V/6A +24V/8A -24V/4A 5V/60A 12V/25A 15V/20A 24V/12A
General Specifications
Dielectric Strength Remote On/Off (Optional) Power Fail Signal Remote Sense (Outputs 1 &2) Weight 4250 VDC, Primary to Secondary, 1 Sec. 2150 VDC, Primary to Ground, 1Sec. 500 VDC, Secondary to Ground, 1 Sec. Contact closure shuts off all outputs. Logic low with input power failure 2mS minimum prior to output one dropping 1% 250 mV compensation of output cable losses 3.3 Lbs.
Electromagnetic Compatibility Specifications
Electrostatic Discharge Radiated Electromagnetic Field EFT Surges Radiated Emissions Conducted Emissions Harmonic Current Emissions IEC 801-2 IEC 801-3 IEC 801-4 IEC 801-5 EN 55022, EN 55022, EN 61000-3-2 8kV Air Discharge 3V/M, 26-1000MHz. 2 kV 1kV Differential Mode 2kV Common Mode Class B Class B
NOTES: 1. Consult factory for alternate output configurations. 2. Consult factory for positive, negative or floating outputs. 3. Specify optional overvoltage protection, power fail signal, remote on/off or perforated cover when ordering.
Ph: (570) 824-4666 * Fx: (570) 824-4843
22
CE-300 Series Mechanical Specifications
AC Input Connector TB1:
* Terminal block with 6-32 screws on 0.325 inch centers mates with #6, 0.26 inch wide spade terminals.
Applications Information
1. This product is intended for use as a professionally installed component within information technology equipment. 2. Remote sense terminals (Figure 1) may be used to compensate for cable losses up to 250mV. The use of a twisted pair is recommended as well as a decoupling capacitor CD(0.1 -10F) and a capacitor CL of 100F/Amp connected across the load side. 3. Each output can deliver its full rated current but total output power must not exceed 300 watts. 4. A minimum load of 10% is required on output one to insure proper regulation of remaining outputs. 5. Forced air cooling requires an air speed of 500 LFM flowing past a point one inch above top of perforated cover in any direction. 6. Peak current on output 2 is available for 10 seconds maximum with a 20% duty cycle. 7. Peak to peak output ripple and noise is measured directly at the output terminals of the power supply, without the use of the probe ground lead or retractable tip, 20 MHz. bandwidth. 8. The power supply has been safety approved and final tested using a DC dielectric strength test. Please consult factory before performing an AC dielectric strength test. 9. Maximum screw penetration into chassis mounting holes is .188 inches.
DC Output Connector TB2:
* Terminal block with 6-32 inch screws on 0.325 inch centers mates with #6, 0.26 inch wide spade terminals.
DC Output Studs + and -:
* 10-32 threaded studs mate with #10 ring tongue terminals.
Option/Sense Connector P1:
* .100 inch friction lock header mates with Molex 22-01-2127 or equivalent crimp terminal housing with Molex type 6459 or equivalent crimp terminal.
Figure 1- Output sense connections
Optional perforated cover shown.
Ph: (570) 824-4666 * Fx: (570) 824-4843
23


▲Up To Search▲   

 